Enmet EX-6100 Series Manuale Utente Pagina 14

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 28
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 13
EX-6100
ENMET Corporation
11
Step 4
Remove the sensor board from the rear of the sensor – do not disconnect the wires from the main board.
Step 5
Remove sensor insert using maintenance tool or slip joint pliers.
Step 6
Mark the sensor pin position & undo the snap ring that retains the sensor in its housing.
Step 7
Replace the sensor taking note of the pin marking in step 6.
Vedere la pagina 13